BWFXL - BARIUM PERCHLORATE, 205078

  • MSDS: BWFXL
  • Manufacturer: ICN BIOMEDICALS
  • Product Name: BARIUM PERCHLORATE, 205078
  • National Stock Number: 6810-00N056333
Product Identification

Product ID:BARIUM PERCHLORATE, 205078
MSDS Date:11/21/1989
FSC:6810
NIIN:00N056333
MSDS Number: BWFXL

Responsible Party
ICN BIOMEDICALS
1263 S CHILLICOTHE RD
AURORA, OH 44202
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 216-562-1500

Cage: IO030

Contractor
ICN BIOMEDICALS INC
28050 CLEVELAND, OH 44128-0250 US

Telephone: 216-831-3000

Cage: IO030

Ingredients

PERCHLORIC ACID, BARIUM SALT; (BARIUM PERCHLORATE)

CAS: 13465-95-7

RTECS: SC7550000

Fraction By Weight: 100%

OSHA PEL 5 MG BA/M3

ACGIH TLV: 10 MG BA/M3


CALL MD. MOVE PATIENT TO A HOSPITAL

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SOLUBLE BARIUM SALTS SUCH AS CHLORIDE
& SULFIDE ARE POISONOUS WHEN TAKEN BY MOUTH. FEW CASES OF
INDUSTRIAL SYSTEMIC POISONING HAVE BEEN REPORTED, BUT ONE
INVESTIGATOR DESCRIBES A FATAL CASE OF POISONI NG ATTRIBUTED TO
BARIUM OXIDE, THE SYMPTOMS BEING SEV ABDOMINAL PAIN W/VOMITING,
DYSPNOEA, RAPID PULSE(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: PARALYSIS OF ARM & LEG & EVENTUALLY
CYANOSIS & DEATH. THE SAME INVESTIGATOR PRDCED PARALYSIS IN ANIMALS
W/BARIUM OXIDE & CARBONATE. THE USUAL RSLT OF EXPOS TO SULFIDE,
OXIDE & CARBONATE IS I RRIT OF EYES, NOSE & THROAT & SKIN, PRDCG
DERM. SALTS ARE SOMEWHAT CAUSTIC. IRRITANT. POISONOUS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:RINSE LIBERALLY W/SOAP & WATER FOR A CONSIDERABLE
PERIOD. IN CASE OF GENL DISORDERS CALL MD/MOVE PATIENT TO HOSP.
INGEST:IF W/IN 15 MINS AFTER OCCUR, MAKE PATIENT DRINK 1-2 GLASSES
OF WATER. INDU CE VOMIT. ALWAYS CALL MD. MOVE PATIENT TO HOSP
IMMED. EYES:RINSE LIBERALLY W/WATER FOR AT LEAST 15 MINS.
SEND/BRING PATIENT TO MD/HOSP. INHAL: TAKE PATIENT TO FRESH AIR &
ALLOW TO REST. ALWAYS (ING 2)

Fire Fighting

Extinguishing Media:WATER OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. FIRE HAZ: MODERATE, BY CHEMICAL REACTION;
POWERFUL OXIDIZER.
Unusual Fire/Explosion Hazard:MOD, WHEN SHOCKED/EXPOS TO HEAT/BY CHEM
RXN. PERCHLORATES, WHEN MIX W/CARBONACEOUS MATL, FORM EXPLO MIXS.
THEY ARE CONSDIERED A FIRE & EXPLO HAZ WHEN (SUPDAT)

Accidental Release

Spill Release Procedures:SWEEP INTO SUITABLE CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PERCHLORATES ARE UNSTABLE MATERIALS &
ARE IRRITATING TO SKIN & MUCOUS MEMBRANES WHEREVER THEY COME IN
CONTACT. AVOID SKIN CONT W/THESE MATERIALS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED DUST MASK.
Ventilation:LOCAL EXHAUST REQUIRED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES.
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE BATH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: ASSOC W/CARBONACIOUS MATLS/FINELY DIVIDED METALS. IS ALSO
TRUE OF THE PRESENCE OF SULFUR, POWDERED MAGNESIUM & ALUMINUM.
REACT VIOLENTLY W/BENZENE, CAH*2, CHARCOAL, OLEFINS, ETHANOL,
SRH*2S H*2SO*4. MATL TO AVOID: VIOLENTLY W/BENZENE, CAH*2,
CHARCOAL, OLEFINS, ETHANOL, SRH*2*SH*2*SO*4.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:941F,505C
Spec Gravity:3.2
Solubility in Water:SOLUBLE
Appearance and Odor:POWDER.

Stability

Stability Indicator/Materials to Avoid:NO
OXIDIZING MATERIALS. CARBONACEOUS MATLS, FINELY DIVIDED METALS, SULFUR,
POWDERED MAGNESIUM & ALUMINUM, REACTS (SUPDAT)
Stability Condition to Avoid:AVOID SHOCK.
Hazardous Decomposition Products:TOXIC FUMES OF CL-.

Disposal

Waste Disposal Methods:INCINERATE OR LANDFILL AS COMPLIES WITH LOCAL,
STATE & FEDERAL LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.